FEATURES | ||
7 Stage Charging | ||
Intelli-Charge battery chargers use intelligent electronics to monitor the charging process and deliver an advanced 7-stage charge to your battery. 7-stage charging is a very comprehensive and accurate charging technique that gives your battery longer life and better performance compared to using traditional chargers. | ||
Multi-Chemistry | ||
The multi-chemistry function allows you to set the charging profile to suit the battery’s chemistry type (GEL, AGM, WET and Calcium). This ensures correct and thorough charging and maximises battery performance and battery life. | ||
User-Friendly Controls | ||
All Intelli-Charge chargers feature user-friendly displays so you can quickly customise the charge settings and monitor the charger’s performance. What’s more, the Chargers remember the last settings used even when the power has been turned off. | ||
Short Circuit Protection | ||
Projecta Intelli-Charge battery chargers feature short circuit protection, Designed to prevent the output leads from sparking during charging from an accidental reverse connection or short circuit, Projecta gives you peace of mind that the charger will remain safe at all times. | ||
Shock Proof & Dust Proof | ||
Constructed from extruded aluminium, Intelli-Charge battery chargers are shock-proof, dust-proof and have been rigorously vibration tested and passed both a military and caravan standard. In addition, the circuit boards have been conformal coated to protect against moisture and dust and other elements so they are suitable for use in a range of locations.
|
SPECIFICATIONS | |||
TYPE | 7 stage | ||
INPUT | 240VAC, 50Hz | ||
INPUT POWER | 216W | ||
OUTPUT VOLTAGE | 12V | ||
OUTPUT CURRENT | 7A | ||
MINIMUM START VOLTAGE | 2.5A | ||
BACK DRAIN | 1mA | ||
CHARGE CONTROL: | |||
DESULPHATION | High Frequency Pulse charge up to 11V | ||
SOFT START | Half the rated set current up to 12V | ||
BULK | Set current up to: 14.1V (GEL) 14.4V (AGM) 14.7V (WET) 14.7V (CALCIUM) |
||
EQUALIZATION | Contact current (2.0-3.75A) up to 16V then hold for 1 hour or 12 hour timeout | ||
ANALYSIS | Monitors battery for 90 sec | ||
RECONDITION | Constant current (0.3-3.75A) for 4 hours limited to: 14.1V (GEL) 14.4V (AGM) 14.7V (WET) 16V (CALCIUM) |
||
FLOAT | 13.7V | ||
BATTERY RANGE: | |||
DEEP CYCLE | 50-140Ah | ||
AUTOMOTIVE | 300-800CCA | ||
MARINE | 350-900MCA | ||
TYPES OF BATTERIES | Most types of lead acid batteries including GEL, AGM, WET CELL and CALCIUM | ||
SIZE (MM) | 182x61x108 | ||
WEIGHT | .95 Kg | ||
POWER SUPPLY: | |||
SET VOLTAGE | 13.8V | ||
MAXIMUM CURRENT | 7A |